Systems

S4 PIONEER, 4kw Location: Karlsruhe
Age: about 5 years  
   
Specification:  
- SN 202656, ex AML 32500507  
   
Configuration:  
- S4 PIONEER WITH 60 POSITION SAMPLE CHANGER 7KP1062, exact details on application  
   
- Warranty period on application  
- Shipment terms EXW Karlsruhe acc. to Incoterms 2000  
- For more information, please contact the above mentioned service persons.  
SMART X2S Automated Bench Top System 110
240V AC 50/60Hz with SN 4150
Location: Karlsruhe
Age: about 1 year  
Warranty: 1 year  
   
Remark:  
- Shipment terms EXW Karlsruhe acc. to Incoterms 2000  
- For more information, please contact the above mentioned service  
   
SMART X2S Automated Bench Top System 110
240V AC 50/60Hz with SN 4085
Location: Karlsruhe
Age: about 1 year  
Warranty: 1 year  
   
Remark:  
- Shipment terms EXW Karlsruhe acc. to Incoterms 2000  
- For more information, please contact the above mentioned service  
   
S4 PIONEER Location: Karlsruhe
Age: about 5 years  
   
Specification:  
- SN 202793, ex SAP 602766  
   
Configuration:  
S4P  
S4 with He  
60 pos. PW  
10 Sample Cups 34 mm Steel  
SC, FC  
Crystals LiF200, Ge, PET, XS55, XS-C  
Collimators: 0,23°, 0,46°, 1°  
Tube AG 66 used ca. 1 year old  
   
Remark:  
- Warranty period 6 months  
- Shipment terms EXW Karlsruhe acc. to Incoterms 2000  
- For more information, please contact the above mentioned service persons.  
   

Components

WATER-TO-AIR REFRIGERATED HEAT EXCHANGER, SINGLE PUMP
Age: 7 years
 
R100 Mechanically refrigerated heat exchanger uses low-pressure refrigerant. Heat removal capacity 3,150 Watts with 80 F cooling air.
 
Includes option ABOR:
- flowmeter, high-temperature thermostat to shut off pump
- manual shut-off valves
- and high-capacity pump.
 
Remark:
- Not used before!
- No warranty
- Price on request
- For more information, please contact the above mentioned service persons.
MONTEL200 MULTILAYER OPTICS FOR 2ND PORT OF MICROSTAR RA X-RAY GENERATOR
Part No: 592465
 
High Brilliance Multilayer Optics with complete alignment hardware featuring:
 
- Unequalled brilliance, with very high monochromaticity
- Secondary focusing distance of 380 mm
- Complete hardware integration and interface for direct coupling of mirrors to X-ray tube providing maximal stability
- Easy and simple alignment by using two orthogonal micrometer translations and two orthogonal micrometer rotations
- Supplied with vacuum pump enabling operation in vacuum.
 
Remark:
- For more information, warranty, and prices, please contact the above mentioned service persons.
HELIOS Cu X-RAY OPTICS FOR MICROSTAR OR FR591 Location: Karlsruhe
Part No: 591468  
   
High Brightness Multilayer Optics for use on X8 PROTEUM/FR591or MicroSTAR with Copper (K-alpha) radiation with complete alignment hardware featuring:  
   
- Unequalled brilliance, with very high monochromaticity  
- Secondary focusing distance of 300 mm  
- Complete hardware integration and interface for bayonet coupling of mirrors to RA port providing maximal stability  
- Easy and simple alignment by using two orthogonal micrometer translations and two orthogonal micrometer rotations  
- Supplied with vacuum pump enabling operation in vacuum 50/60Hz and 230/110V  
- X-ray safety assurance system  
- Divergency limitations for use with X8 PROTEUM.  
   
Remark:  
- Warranty on application  
- For more information and prices, please contact the above mentioned service persons.  
- Price on application  
WATER CHILLER Location: Karlsruhe
   
Age: about 2,5 years  
   
External closed cooling-water circuit for cooling of Turbo X-ray source generator and tower. The waste heat is exhausted into the air, therefore an external installation is recommended.  
   
Technical data:  
- Cooling capacity: 20 kW at ambient temperatures of up to 32°C  
- Water reservoir: 200 l  
- Water conditions cooling circuit:  
- temperature: 18°C  
- flow: 20 l/min at 3.5 bar  
- Automatic safety switch off at excessive temperature and excess pressure  
- Dimensions: 855 x 1360 x 1752 mm, w x d x h, another 0.5 m space required in each direction for a proper installation.  
- Weight: 470 kg  
   
Requirements:  
- Mains supply voltage: 400 V / 3 phases / 50 Hz  
- Cooling water for the reservoir needs to be of be-distilled quality  
   
Remark:  
- Type ERL K140A1  
- Warranty 6 months  
- For more information and prices, please contact the above mentioned service persons.  
- Price on application  
SOL-X SOLID STATE DETECTOR FOR D8 Location: Karlsruhe
   
The Sol-X solid state detector is a energy dispersive X-ray detector suitable for X-ray diffraction experiments using energies between 2 keV and 30 keV. The Lithium drifted Silicon detector (Si(Li)) chip is cooled down to about -80°C by Peltier elements. The chip is mounted in a small vacuum reception having a Be entrance window for the incoming X-rays. The detector is mounted equivalent to a scintillation counter. The obtained count rate is transferred to the measurement electronics of the diffraction system.  
   
Remark:  
- ex Works Karlsruhe  
- Warranty 6 months  
- For more information and prices, please contact the above mentioned service persons.  
- Price on application  
COBRA LOW TEMPERATURE DEVICE WITH DEDICATED NITROGEN GAS GENERATOR, 50HZ/230V Location: Karlsruhe
   
It uses nitrogen gas, provided by an included Nitrogen gas generator, to produce a constant cold stream of nitrogen, down to a temperature of 80K.  
The nitrogen gas is cooled by the Cobra refrigerator (Gifford McMahon principle), and delivered to the Cobra head via a vacuum insulated transfer line. The Cryodrive and refrigerator can be kept outside the X-ray enclosure.  
An external stream of nitrogen gas at room temperature creates a shielding laminar flow, which prevents icing on the sample.  
   
Specifications:  
- Temperature range 80-400 K  
- Nitrogen gas flow rate 5 or 10 l/minute  
- Temperature stability 0.1 K  
- Cool down time to 100 K in 30 minutes  
- Coldhead weight 1.5 g  
- Length of transfer line (to end of nozzle) 2000 mm  
   
The Cobra consists of:  
- Cobra gas delivery head*, Cryostream style nozzle  
- 2 m flexible vacuum hose connecting head & refrigerator*  
- Cobra refrigerator incorporating a single stage GM coldhead*  
*The first 3 items can not be physically separated  
- Programmable temperature controller  
- Water-cooled GM refrigerator compressor (Cooling unit is not included)  
- Varibeam support stand  
- Nitrogen gas generator  
   
- For more information and prices, please contact the above mentioned service persons.  
- Price on application  
VIDEO ZOOM MICROSCOPE FOR D8, 214 MM Location: Karlsruhe
   
Color CCD video camera plus optical lens. Mounts to the base of SMART and PROTEUM/D8 Systems.  
   
Remark:  
- Price without installation  
- ex Works Karlsruhe  
- Delivery: on stock  
- Warranty 6 month  
- For more information and prices, please contact the above mentioned service persons.  
- Price on application  
KRYO-FLEX LOW TEMPERATURE EQUIPMENT Location: Karlsruhe
Age: about 1 1/2 years  
   
Low-consumption and highly stable Low-Temperature device based on a heat-exchanger principle.  
   
- Temperature range of < 90 K to 300 K  
- Stability of +/- 0.1 K  
- Nitrogen consumption < 0.5 l/hr  
- Electronic, user controlled gas-flow rate  
- 3000 mm flexible transfer line; will pass through D8 labyrinth  
- Extremely quiet pump as 19.-rack unit  
- Control electronics as 19.- rack unit  
- Safety features to check for Nitrogen gas flow present and  
- 60 l dewar included for 5 days autonomous operation  
- Automatic refill from optional supply dewar  
- Software control  
- Verification of the temperature in close vicinity of the  
- Nozzle with secondary dry air stream to avoid icing  
   
Remark:  
- Price without installation  
- ex Works Karlsruhe  
- Delivery: on stock  
- Warranty 6 month  
- For more information and prices, please contact the above mentioned service persons.  
- Price on application